loading

MERITSUN Battry - The Best Battery Energy Storage System & Lithium Battery Solutions Provider.

arduino true battery capacity tester (li-ion/nimh/nicd/pb) - li ion battery cell

arduino true battery capacity tester (li-ion/nimh/nicd/pb)  -  li ion battery cell

If anyone sees my last instructions
They can now upgrade to computerized hi-
Technical version capable of measuring almost any type of rechargeable or unrechargeable battery (
But in the process it consumes a charge from them).
It can even connect to the pc and provide you with the full "data-
Chart of emissions and total capacity.
Please note that this is my first Arduino project (
I don't count my "flashing LED ").
This is the chart obtained during the drain cycle from the text file sent to PCduring.
I really wanted to get this Diecimila copy Arduino board bit and it took me about 2 weeks to get it by mail so I had to start with my own bread --
Arduino board, so I bought a version of the atlag168 and thought I could get it to run without any components. .
It doesn't work for me, I just need to buy another batch of 16 Mhz crystals and two 22 pf hats. .
Then I got the next one. . .
I basically take the garbage apart and add components one by one. . .
Most of the information can be found on the Arduino web page: there's really everything you need.
It took me about a week to get it up and running (
Boot loader/build ISP cable and RS232 cable. . . )-
You can read all the information about this on the website above.
Add a "on" resistor ~ The FET of 8 mOHM is quite simple (
There is no force separation on It)and a 2. 2 10 w resistors.
I connect the two A/D pins of the Arduino to the resistor pole and subtract these values to get the exact voltage drop on the resistor.
Now I sample them every second and calculate the current (I=DeltaV/R).
I also added a buzzer to indicate when the charge will end and stop the discharge.
So I also connected to the LCD (
I separated it from the rest of the garbage)
Found the data.
There is a cool driver on the Arduino web page online and start coding.
Automatically detect battery type according to voltage.
Will it detect whether it is NiMH/NiCD or Li-
Ions within the voltage range.
Then start the discharge cycle.
Discharge can be from 30-
120 minutes depending on the battery capacity, but in the end you will get a real indication of the battery capacity/quality.
Do you want to make air with that battery?
Or no receiver?
This is a schematic diagram of the discharge circuit. . .
Very simple, 2 A/D are connected on both sides of the resistor/Vr = VbatVfet.
/Code for this library: Liquid crystal LCD Display (
12, 11, 5, 4, 3, 2);
/Initialize the library with the number of interface pinsint sensorPin = 0;
/Select the input pin for the potentiometer (pin 23)
Int sensor2Pin = 2;
/Select the input pin for the potentiometer (pin 23)Int ledPin = 13;
/Select pin for LEDint SPKPin = 6;
Int sensorValue = 0;
/Stores variables from values of sensor int sensor2Value = 0;
/Variables to store values from sensor floating threshold = 2700;
/Lithium minimum voltage LiMaxThreshold = 4200 for load removal;
/Maximum lithium voltage nmhminthresold = 950 for load removal;
/NMH minimum voltage floating NMH maximum threshold for load removal = 1600;
/NMH maximum voltage selection threshold for load removal = 5000; int i;
Int BatVoltage = 5000;
Voltage = 5000;
Long total current = 0;
Boolean one = false;
Long, unsigned PrevMillis;
Unsigned long Milli; void CL2(){lcd. setCursor(0, 1);
/The first line of char LCD. print(""); lcd. setCursor(0, 1);
/Line 2 first char}void setup(){Serial. begin(9600);
/Start the serial port to send data to PC pinMode during Operation (ledPin, OUTPUT);
Activation led and enable OF/FET pinMode (SPKPin, OUTPUT);
Activation led and enable for/FET LCD. begin(24, 2);
/Set the number of rows and columns of the LCD: LCD. print(Bat pressurized water reactor Tester [Active]");
/Print a message to the LCD. lcd. setCursor(0, 1);
/The first line of char LCD. print(
"Detect Bat type. . . ");
/Print voltage value delay (2000); lcd. setCursor(0, 1);
/The first line of char LCD. print(""); lcd. setCursor(0, 1);
/Write the first char number in the second line (ledPin, HIGH);
/Set the LED on sensorValue = analogRead (sensorPin);
/Read value from sensor: digitalWrite (ledPin, LOW);
/Set LED off/detect battery type BatVoltage = sensorValue * 4. 887; if (
Batvolage> 4500){lcd. print("Warning high-V! "); done = true; }else if (
BatVoltage> minthresold){lcd. print("Type:Li-Ion Bat ");
SelectedMinThreshold =; }else if (
BatVoltage> nmhminthresold){lcd. print(
"Type: NiMH/Cd Bat";
Select threshold = nmhminthresold; }else{lcd. print(
[Unknown bat V

GET IN TOUCH WITH Us
recommended articles
Knowledge Successful case News
How Long Will a 10 kWh Battery Run a House? A Practical Runtime Guide
Runtime depends on the usable SOC window, conversion efficiency and average backed-up load. Formula, worked example and planning table for 8–15.36 kWh.
Wall-Mounted vs. Floor-Standing Home Batteries: 9 Checks Installers Should Make
Wall-mounted or floor-standing home battery? Run these 9 checks first: wall load, clearances, cabling, environment, inverter communication, expansion.
8 kWh vs. 10 kWh vs. 15.36 kWh Home Batteries: A Load-Shedding Sizing Guide
Compare 8 kWh, 10 kWh and 15.36 kWh home batteries for load-shedding projects — backed-up load, usable capacity, inverter output and reserve, explained.
How to Plan a 30.72 kWh U.S. Home Backup System Around the Load Panel
Learn how to plan a 30.72 kWh U.S. home battery system around a backup-load panel, split-phase service, surge demand and solar recharge.
How to Design a 46.08 kWh Three-Phase Home Battery System for a German Residence
See how installers can plan a 46.08 kWh three-phase home battery system for a German residence, including loads, inverter compatibility and protection.
Can You Add a Battery to an Existing Solar System? AC-Coupled vs. DC-Coupled Retrofit Guide
Learn when an existing solar system can be retrofitted with battery storage, how AC- and DC-coupled designs differ, and what installers must inspect first.
UN 38.3 vs. IEC 62619 vs. UL 1973: A Battery Document Checklist for Distributors and Installers
Learn what UN 38.3, IEC 62619 and UL 1973 cover, what they do not prove, and which product documents distributors and installers should verify.
How to Compare Home Battery Warranties: Years, Cycles, Throughput and Capacity Retention
Compare home battery warranty years, cycle limits, energy throughput, capacity retention, operating conditions and exclusions before selecting a supplier.
What Is Battery C-Rate? How Charge and Discharge Limits Affect Home ESS Power
Understand 0.5C, 1C and other battery C-rates, how to convert current into power, and why the BMS and inverter may limit real home ESS output.
How to Read a Home Battery Datasheet: 12 Specifications Installers Should Verify Before Quoting
Learn how to evaluate capacity, voltage, current, power, cycle life, temperature limits, communications, certifications and warranty terms before quoting a home battery.
Established in 1999, we have 20+ years of energy professional experience and integrated solutions services in energy storage application industrial, and further reach the demands the smart & green energy era. 
Copyright ©1999-2025 MeriTech Power Limited - www.meritsunpower.com | All Rights Reserved | Sitemap | Privacy Policy